Application Tag Commands
80 Command Set
Release Version 1.0.34. The command information in this section has been updated to only
include the new format.
The following fields have been added to all the specified commands. Please check each
command for exact order, and any exceptions, as they may not all correspond with the
order below.
Tag Singulation Fields
Field Values Description
Select Options
1
Select
Contents
(Bits 0,1, 2)
0x00 Select functionality is disabled. First tag found will be the tag
operated on. No other Tag Singulation Fields should be
specified. Option field must always be specified.
Note: When Select is disabled commands do not support
an access password. Use Select Option=0x05 to
send a password without Select.
0x01 Select on the value of the EPC. Requires all fields except
the Select Address field.
0x02 Select on contents of TID memory bank (Gen2 bank 0x02).
Requires all fields.
0x03 Select on contents of User Memory memory bank (Gen2
bank 0x03). Requires all fields.
0x04 Select on contents of the EPC memory bank (Gen2 bank
0x01). Requires all fields.
0x05 Use this option when you need to specify an access pass-
word to operation on locked data but don’t want to perform a
Select. When this option is used do not pass any Select Cri-
teria.
1
Select
Invert
(Bit 3)
0x08 Sets Invert Flag. This results in tags NOT matching the
specified Tag Singulation Fields will be returned, as defined
in
Select Algorithm and Parameters.
1
Extended
Select Data
(Bit 5)
0x20 Changes Select Data Length to 2 bytes, allowing Select
Data to be greater than 255 bits.