Application Tag Commands
Command Set 121
Partial Load Image
Sub Command=0x01
If the first bit of Sub Command is 1 (Sub Command=0x01), the Gen2 Tag Specific
command writes an EPC with a length of up to 96-bits, plus the Kill and Access
passwords without locking in a single command.
The format for this command is as follows:
Full Load Image
Sub Command=0x03
If the second bit of Sub Command is 1 (Sub Command=0x03), the Gen2 Tag Specific
command will also modify the Lock bits (locking the tag according to the Alien Higgs Lock
Bits) and the Alien Higgs PC Bits.
The format is extended as follows:
The Lock Bits correspond to the Higgs TID Bank configuration bits with the same name
and are shown in the following table:
Alien Higgs Lock Bits
FF 18 2D 03 E8 01 01 00 00 00 00 00 00 00 00
SOH Length OpCode Timeout (ms) Chip Type Sub
Com-
mand
Kill Password Access Password
11 22 33 44 55 66 77 88 99 AA BB CC 45 64
Tag ID CRC
FF 1C 2D 03 E8 01 03 01 23 45 67 89 AB CD EF
SOH Length OpCode Timeout (ms) Chip Type Sub
Command
Kill Password Access Password
00 02 30 00 11 22 33 44 55 66 77 88 99 AA BB CC ?? ??
Lock Bits PC Word Tag ID CRC
Bit Number
15 14 13 12 11 10 9 8 7 6
Field Name>
XXXXXX X X X X