Application Tag Commands
126 Command Set
format of the response is:
FastLoadImage embedded in a Read Tag Multiple takes the following form:
LoadImage
Sub Command=0x0003
This command writes all of the following data to the Higgs3 tags in a single command,
thereby reducing the tag programming time compared to the use of multiple Write Tag
Data (24h) commands.
Reserved Memory
EPC Memory
User Memory
FF 09 2D 00 00 05 44 00 01 XX XX ... ?? ??
SOH Length OpCode Status Chip
Type
Option Sub
Cmd
EPC Data CRC
FF 19 22 04 00 04 03 E8
11 22 33 44 00 00 00 78 08 38
SOH Length OpCode Options
(EPC Mem)
Search
Flags
Timeout Access Password Select Data Address
(bits)
Select
Data
Length
(bits)
Select
Data
01 1F 2D
00 00
05 40
00 01
Embd
Cmd
Count
Embd
Cmd
Length
Embd
Cmd
OpCode
Embd Cmd
Timeout
(Not Used)
Chip
Type
Option Sub Cmd
11 11 22 22 00 00 00 00 11 22 33 44 XX XX (12 bytes) ?? ??
Current Access Pwd Kill Password New Access Password PC Word EPC Data CRC